Products AgWireCopper Tray Control Cable

Copper Tray Control Cable

P7393D-AG
Legacy:
Product Type

Direct Burial Control

Gauge Size

10-16 AWG

Jacket

PVC

Voltage

600

Insulation

THHN/THWN

Temperature

60°C WET or DRY.

Description
600 VAC direct burial rated copper conductor cable for limited power feeder circuits or control power circuits to remote control distant electric motorized equipment or remote locating of irrigation machine main control panel.
Specifications
Type TC Control Cable meets or exceeds the applicable requirements of the following standards and specifications: ASTM – (All applicable standards) NFPA 70 (NEC) UL 1581 Electrical Wires, Cables & Flexible Cords ICEA S-58-679 – Control Cable Conductor Identification Method 1, Table 2 UL 1685 – UL Flame Exposure Test (70,000 Btu/hr)
Construction

Conductors: Sizes 16 - 10 AWG individual bare annealed copper conductors. 3.1.1 Type THHN or THWN 14 AWG -10 AWG 3.1.2 Type TFFN Multiconductor constructions,

Insulation: THHN/THWN.,

Jacket: Heat, moisture and sunlight resistant PVC. Nonhalogen jacket available upon request.

Application
600 VAC direct burial rated copper conductor cable for limited power feeder circuits or control power circuits to remote control distant electric motorized equipment or remote locating of irrigation machine main control panel.